Listing data from public Google Maps listings and each company's own website (services and pricing, checked Nov 23, 2026), as of Nov 23, 2026. Always check hours and conditions before you go.
Home › Guides › Egress windows & window wells

Basement egress window and window well requirements in Utah

Last updated · By the Utah Basement Finishers team · Sources at the bottom

Family room with a sectional sofa and a wall of large windows
Stock photo, not a listed company's work.
At a glance

Utah follows the 2021 International Residential Code. Every basement sleeping room needs an emergency escape opening with at least 5.7 sq ft of net clear opening (5 sq ft at grade floor), at least 24 inches high and 20 inches wide, with the bottom of the opening no more than 44 inches above the floor. A below-grade window needs a well of at least 9 sq ft, 36 inches wide and deep, with a ladder if it is deeper than 44 inches.

  • 102 of the 394 basement companies we list (26%) mention egress windows on their website.
  • The minimums are net clear opening: the space you can climb through with the window fully open, not the size of the glass.
  • Utah adds a few statewide amendments to section R310; check with your city before you cut a new opening.

The rules, in plain terms

RequirementMinimum or maximumCode section
Which roomsEvery basement sleeping room; a basement without bedrooms needs at least one openingR310.1
Net clear opening area5.7 sq ft (5.0 sq ft for a grade-floor opening)R310.2.1
Net clear height24 inches minimumR310.2.2
Net clear width20 inches minimumR310.2.2
Sill heightBottom of the clear opening no more than 44 inches above the floorR310.2.3
OperationOpens from inside without keys, tools or special knowledgeR310.1.1
Window well sizeAt least 9 sq ft, with at least 36 inches of width and projectionR310.4.1
Ladder or stepsRequired if the well is deeper than 44 inchesR310.4.2
Well covers and gratesMust be releasable from inside without a key, tool or extra forceR310.4.4

From the 2021 IRC as adopted in Utah. Utah's statewide amendments (Utah Code 15A-3-202) change parts of R310, including an exception related to accessory dwelling units. Your city's plans examiner has the final word.

Why many windows don't qualify

A window can be big and still fail. A sliding window that is 48 inches wide opens only about half its width, and the frame takes some of that. Check the manufacturer's published net clear opening, not the rough opening. Casement windows usually give the most clear opening for their size.

Window wells

  • The well has to let the window open fully.
  • A ladder or steps can stick into the required well size by up to 6 inches.
  • Covers keep out snow and kids but must open easily from inside.
  • Wells collect water; ask your contractor about drainage at the bottom of the well.

Adding an egress window

If your basement has small hopper windows, adding a bedroom means cutting a larger opening in the foundation, installing a well, and usually a permit for structural work. Many Utah basement companies do this themselves; 102 mention it on their sites. Ask for it as a separate line in your quote.

Companies that mention egress windows (102)

Most-reviewed first. Look for "Egress windows" on any listing.

Universe Construction

Lehi, UT · Utah County
Basement Finishing Specialists $52 /sq ftBasement apartments
★ 4.8 (135 Google)

Questions people ask

What size egress window is required in a Utah basement?

At least 5.7 sq ft of net clear opening (5 sq ft at grade floor), at least 24 inches high and 20 inches wide, with the bottom of the opening no more than 44 inches above the floor (2021 IRC R310, as adopted in Utah).

Does every basement need an egress window?

The 2021 IRC requires basements to have at least one emergency escape opening, and every basement sleeping room needs its own. There are narrow exceptions, such as a small basement used only for mechanical equipment.

How big does a window well have to be?

At least 9 sq ft in area, with at least 36 inches of width and projection from the wall, and big enough for the window to open fully. Wells deeper than 44 inches need a permanent ladder or steps.

Can a basement bedroom be legal without a window?

Not normally. A sleeping room needs an emergency escape opening, which can be a window or a door to the outside that meets the code. Ask your city about any exception before you plan the room.

Who installs egress windows and window wells in Utah?

102 of the 394 basement companies in our directory mention egress windows on their websites, and 27 mention window wells. The most-reviewed are listed on this page.

Sources

  1. Utah Code 15A-2-103: 2021 IRC adopted statewide
  2. Utah Code Title 15A, Chapter 3, Part 2: statewide amendments to the IRC
  3. South Jordan: Basement finish code requirements (2021 IRC, R310)

General information, not legal, engineering or financial advice. Codes, fees and city rules change; confirm with your city or county building department and the official sources above before you sign or build. Company prices and timelines are what each company posted on its own website when we checked (Nov 23, 2026); they are not quotes.